Search results for "Attenuated total reflection"

showing 10 items of 67 documents

Screening archaeological bone for palaeogenetic and palaeoproteomic studies.

2020

Funder: FP7 Ideas: European Research Council; funder-id: http://dx.doi.org/10.13039/100011199; Grant(s): 295729

1100Proteomics1300Social SciencesMarine and Aquatic Sciences01 natural sciencesBiochemistrySpectroscopy Fourier Transform InfraredLimnologyScreening method0303 health sciencesMultidisciplinaryAncient DNAChemistryFossilsQRFOS: Social sciencesNucleic acidsArchaeologyAttenuated total reflectionMedicinePhysical AnthropologyOrganic contentResearch Article1000010506 paleontologyScienceInfrared spectroscopyPaleoenvironmentsBone and Bones03 medical and health sciencesPaleoanthropologyGeneticsAnimalsHumansPaleolimnologyDNA AncientPaleozoology030304 developmental biology0105 earth and related environmental sciencesEcology and Environmental SciencesBiology and Life SciencesProteinsPaleontologyDNAArchaeologyEarth sciencesAncient DNAAnthropologyPaleobiologyPaleogeneticsCollagensPloS one
researchProduct

ATR-Spin: an open-source 3D printed device for direct cytocentrifugation onto attenuated total reflectance crystals.

2021

Infrared Spectroscopy (IR) enables the direct and rapid characterization of cells at the molecular level. Achieving a rapid and consistent cell preparation is critical for the development of Point-of-Care diagnostics for cell analysis. Here we introduce an open-source, 3D printed device for integrating the isolation, preconcentration, and measurement of attenuated total reflectance IR spectra of cells from biofluids. The tool comprises a disposable card for cytocentrifugation, equipped with magnets, which allows reproducible integration into the pathlength of the IR spectrophotometer. Preliminary results using cell media containing A459 cells indicate that this system enables a qualitative …

3d printedMaterials scienceSpectrophotometry Infraredbusiness.industryCell preparation010401 analytical chemistryBiomedical EngineeringInfrared spectroscopyBioengineeringCell analysis02 engineering and technologyGeneral Chemistry021001 nanoscience & nanotechnology01 natural sciencesBiochemistry0104 chemical sciencesOpen sourceMolecular levelAttenuated total reflectionPrinting Three-DimensionalSpectroscopy Fourier Transform InfraredOptoelectronics0210 nano-technologybusinessLab on a chip
researchProduct

Plasmonic modes in molybdenum ultra-thin films suitable for hydrogenated amorphous silicon thin film solar cells

2014

We have recently demonstrated that molybdenum ultra-thin films interposed between hydrogenated amorphous silicon (a-Si:H) and SnO2:F transparent conductive oxide (TCO) in thin film solar cells show light trapping effects which enhance the solar cells performances. The effect of this improvement may be attributed to surface plasmon polariton (SPP) modes excited at the molybdenum interface by the solar radiation. In this paper we show direct evidence of such SPP modes in the case of the molybdenum/air interface by using the attenuated total reflection (ATR) technique, pioneered by Kretschmann, and we evaluate the dielectric constant of molybdenum at 660 nm. (C) 2013 The Authors. Published by …

Amorphous siliconMaterials sciencebusiness.industrychemistry.chemical_elementThin Film PhotovoltaicsThin Film PhotovoltaicPlasmonicSurface plasmon polaritonThin Film Photovoltaics;Light Trapping; Plasmonics;Hydrogenated Amorphous Siliconchemistry.chemical_compoundHydrogenated Amorphous SiliconEnergy(all)chemistryMolybdenumAttenuated total reflectionOptoelectronicsPlasmonicsPlasmonic solar cellThin filmbusinessPlasmonLight TrappingTransparent conducting film
researchProduct

Quantification of minerals from ATR-FTIR spectra with spectral interferences using the MRC method.

2017

A method for quantifying the individual components of mineral samples based on attenuated total reflectance - Fourier transform infrared spectroscopy (ATR-FTIR) is described, extending the constant ratio (CR) method to analytes absorbing in a common range of wavenumbers. Absorbance values in the spectral region where the analytes absorb relative to the absorbance of an internal standard absorbing at a wavenumber where the analytes do not absorb, permits the quantification of N analytes using measurements at N fixed wavenumbers. The method was tested for mixtures of albite, orthoclase, kaolin and quartz.

AnalyteChemistryAnalytical chemistry02 engineering and technology010501 environmental sciencesengineering.material021001 nanoscience & nanotechnology01 natural sciencesAtomic and Molecular Physics and OpticsAnalytical ChemistryFtir spectraAbsorbanceOrthoclaseAlbiteAttenuated total reflectionengineeringFourier transform infrared spectroscopy0210 nano-technologyInstrumentationQuartzSpectroscopy0105 earth and related environmental sciencesSpectrochimica acta. Part A, Molecular and biomolecular spectroscopy
researchProduct

Nutritional parameters of commercially available milk samples by FTIR and chemometric techniques

2004

Abstract A chemometric study on the prediction of the main nutritional aspects of milk has been carried out by using fourier transform infrared spectroscopy (FTIR) attenuated total reflectance (ATR) measurements of commercially available milk samples of different types. Whole, semi and skimmed milks, enriched or not with calcium, vitamins or modified by alteration of lipid or sugar composition were considered. After evaluating different strategies for data acquisition and ATR cleaning between samples, hierarchical cluster analysis (HCA) was carried out for classification of samples in order to choose the calibration set. The prediction capabilities of partial least squares (PLS) data treatm…

AnalyteChemistryAnalytical chemistryInfrared spectroscopyBiochemistryStandard deviationFourier transform spectroscopyAnalytical ChemistryChemometricsAttenuated total reflectionPartial least squares regressionEnvironmental ChemistryFourier transform infrared spectroscopySpectroscopyAnalytica Chimica Acta
researchProduct

Identification and determination of synthetic cannabinoids in herbal products by dry film attenuated total reflectance-infrared spectroscopy.

2017

A new procedure has been developed for the identification and quantitative determination of synthetic cannabinoids in illicit herbal preparations. The methodology is based on the use of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) measurement of sample extracts with 2-propanol drying 5µL of the extracts onto the ATR crystal. The qualitative identification was carried out on the 2-propanol extract after identification of the herbal matrix, followed by its subtraction and using a cut-off criterion of 75%. Quantitative determination was made by univariate calibration using the absorbance of the band located at 1520cm-1 of the spectrum. Four different cannabin…

AnalyteChromatographyChemistryCannabinoidsPlant Extracts010401 analytical chemistryInfrared spectroscopy01 natural sciences0104 chemical sciencesAnalytical ChemistryMatrix (chemical analysis)Absorbance03 medical and health sciences0302 clinical medicineAttenuated total reflectionSynthetic cannabinoidsCalibrationSpectroscopy Fourier Transform InfraredmedicineCalibration030216 legal & forensic medicineFourier transform infrared spectroscopymedicine.drugTalanta
researchProduct

Analytical potential of mid-infrared detection in capillary electrophoresis and liquid chromatography: a review.

2010

Literature published in the last decade concerning the use of mid-infrared spectrometry as a detection system in separation techniques employing a liquid mobile phase is reviewed. In addition to the continued use of isocratic liquid chromatographic (LC) techniques, advances in chemometric data evaluation techniques now allow the use of gradient techniques on a routine basis, thus significantly broadening the range of possible applications of LC-IR. The general trend towards miniaturized separation systems was also followed for mid-IR detection where two key developments are of special importance. Firstly, concerning on-line detection the advent of micro-fabricated flow-cells with inner volu…

AnalyteChromatographyEnvironmental analysisChemistryCapillary actionMicrofluidicsBiochemistryMicellar electrokinetic chromatographyAnalytical ChemistryChemometricsCapillary electrophoresisAttenuated total reflectionEnvironmental ChemistrySpectroscopyAnalytica chimica acta
researchProduct

Chemometric determination of lipidic parameters in serum using ATR measurements of dry films of solvent extracts

2013

Attenuated total reflectance (ATR) infrared spectroscopy of dried organic extracts of serum samples has been evaluated as a fast method for the determination of triglycerides, cholesterol, high density lipoprotein (HDL) and low density lipoprotein (LDL). After careful selection of solvents based on green parameters, serum samples were extracted using hexane-isopropanol and ethyl acetate-ethanol mixtures. Microscopy studies and comparison with standard spectra were performed in order to investigate whether the proposed methodology is suitable for the quantification of lipids in serum samples. The results of these preliminary studies confirmed that the variations in the IR spectra of sample e…

AnalyteChromatographySpectrophotometry InfraredCholesterolCholesterol HDLExtraction (chemistry)Analytical chemistryInfrared spectroscopyCholesterol LDLBiochemistryAnalytical ChemistrySolventchemistry.chemical_compoundchemistryLow-density lipoproteinAttenuated total reflectionSpectroscopy Fourier Transform InfraredPartial least squares regressionSolventsElectrochemistryHumansEnvironmental ChemistryTriglyceridesSpectroscopyThe Analyst
researchProduct

Attenuated Total Reflection-Fourier transform infrared analysis of the fermentation process of pineapple

2005

Abstract A direct and reagent free procedure has been developed to monitor the fermentation process of pine apple nectar using Attenuated Total Reflectance Fourier-transform mid-infrared spectrometry (FT-IR) and multivariate analysis. A classical 4 2 design for standards was employed for calibration using the information in the spectral range from 907 to 1531 cm −1 of the first order derivative spectra after mean centering of infrared data. The root mean square error of calibration (RMSEC) of 0.040, 0.021, 0.063 and 0.074% w/w were obtained for glucose, fructose, saccharose and ethanol, respectively, and a mean relative validation error of 2.9, 2.1, 2.6 and 3.6% was achieved for glucose, fr…

Analytical chemistryInfrared spectroscopyFructoseAlcoholBiochemistryFourier transform spectroscopyAnalytical Chemistrychemistry.chemical_compoundchemistryAttenuated total reflectionEnvironmental ChemistryFermentationFourier transform infrared spectroscopySugarSpectroscopyAnalytica Chimica Acta
researchProduct

Attenuated total reflectance infrared determination of sodium nitrilotriacetate in alkaline liquid detergents

2005

Abstract An attenuated total reflectance infrared (ATR–FTIR) method has been developed for the direct determination of the chelating agent sodium nitrilotriacetate (NTA) in high pH cleaning formulations. Aqueous samples and standards were placed directly on the diamond ATR cell without any pre-treatment and FTIR spectra were recorded between 4000 and 600 cm−1. Measurement conditions were evaluated. Results obtained for five different commercial formulations containing from 6.22 to 9.25% (w/w) of NTA were in good agreement with the manufacturer's declared content (differences between 3.2 and −3.7%). Recovery studies evidenced the accuracy of the developed method, having found values between …

Aqueous solutionchemistryInfraredAttenuated total reflectionSodiumAnalytical chemistryInfrared spectroscopychemistry.chemical_elementChelationQuantitative analysis (chemistry)Fourier transform spectroscopyAnalytical ChemistryNuclear chemistryTalanta
researchProduct